- Chinese Optics Letters
- Vol. 24, Issue 11, 111901 (2026)
Abstract
1. Introduction
The rapid advancement of ultrafast laser technology, particularly through breakthroughs in high-order harmonic generation (HHG) and attosecond pulse production[1–3], has established indispensable capabilities for probing electron dynamics[4–7] at the atomic scale with unprecedented temporal resolution. These developments have empowered a wide range of cutting-edge applications, from attosecond and strong-field physics to pump-probe studies at free-electron laser facilities, where high-power, high-repetition-rate ultrashort pulses are increasingly demanded. Although Ti:sapphire[8–10] laser systems have historically served as workhorses in ultrafast science, their inherent limitations in average power and repetition rate have motivated the adoption of ytterbium (Yb)-doped laser systems[11–15]. Compared with Ti:sapphire amplifiers, Yb-doped amplifiers (e.g., fiber or thin-disk architectures) offer superior thermal management, enabling extremely high average powers (kW level) and high repetition rates (hundreds of kHz to MHz range), along with a more compact system and higher pump efficiency, leading to significantly lower overall cost and maintenance. Nevertheless, the restricted gain bandwidth of Yb-based media typically confines output pulse durations to the range of several hundred femtoseconds, falling short of the sub-20-fs regime required for many advanced experiments.
To bridge this gap, nonlinear post-compression has emerged as a key technique for reducing pulse durations. Established spectral broadening methods include gas-filled hollow-core fibers (HCFs)[16,17], multiple solid thin plates (STPs)[18,19], and multi-pass cells (MPCs)[20,21]. Among these, gas-filled MPCs have garnered significant attention in recent years due to their compact geometry, tunable nonlinearity, and compatibility with high-energy, high-average-power operation. The foundational architecture for such cells was introduced by Herriott et al., and as such, it is commonly referred to as a Herriott-type multi-pass cell[22]. Originally demonstrated in a multi-pass configuration to extend the interaction length for laser spectroscopy in gases, the Herriott cell was proposed by Schulte et al. in 2016 for the application of nonlinear spectral broadening[20]. HCFs provide excellent beam quality, mature technology, and few-cycle compression, but they require precise alignment, are very sensitive to beam pointing, and have low transmission efficiency. STPs offer octave-spanning spectral broadening, single-cycle compression, and a compact all-solid-state design, yet they suffer from low damage thresholds, poor energy scalability, degraded beam quality, and strong spatiotemporal coupling. In contrast to conventional HCFs and STPs, MPC systems provide not only higher transmission efficiency and excellent beam quality, but they also effectively suppress ionization-induced distortions and spatio-temporal coupling effects. As such, they represent a robust and scalable platform for generating high-power, few-cycle pulses, which are essential for driving the next generation of strong-field and ultrafast spectroscopy experiments.
In recent years, post-compression based on MPC has driven remarkable progress in ultrafast laser technology. Numerous groups have demonstrated the compression of pulses from several hundred femtoseconds down to the few-cycle regime[27–37], with pulse energies spanning from microjoules to hundreds of millijoules[23–29,31,36] and peak powers reaching tens to hundreds of gigawatts[31]. A notable contribution by Balla et al. employed a cascaded gas-filled MPC to compress 1.2 ps pulses from a Yb:YAG amplifier to 13 fs, achieving a total compression factor of greater than 90 and highlighting the potential for high-energy few-cycle pulse generation[36]. In another landmark study, Hädrich et al. compressed 260 fs pulses from a fiber laser to 5.8 fs using a two-stage MPC, delivering 107 W average power and 1.07 mJ pulse energy with excellent carrier-envelope phase stability, setting a new standard for high-repetition-rate few-cycle sources[37]. Goncharov and colleagues further advanced the field using cascaded dielectric-mirror-based MPCs, compressing 230 fs, 12 µJ pulses to 6.9 fs with 84% efficiency[33,38]. In their 2024 follow-up study, the technique was applied to a self-developed high-power thin-disk oscillator, compressing 120 fs, 12.8 µJ pulses to 8 fs. The system achieved an average power of 148 W and a peak power of 0.9 GW at 14 MHz repetition rate, with an overall efficiency of 82%. These studies underscore key advantages of MPC technology, including high efficiency, excellent beam quality, and precise dispersion control. In addition, Table 1 summarizes several representative high-power, high-repetition-rate MPC results, including those from the present work, which were not discussed in detail in this section, thereby providing a concise performance comparison for reference.
Sign up for Chinese Optics Letters TOC. Get the latest issue of Chinese Optics Letters delivered right to you!Sign up now
| Unit | Ref. [ | Ref. [ | Ref. [ | Ref. [ | Ref. [ | This work | |
|---|---|---|---|---|---|---|---|
| τinput | fs | 590 | 200 | 200 | 1240 | 1000 | 404 |
| τoutput | fs | 30 | 31 | 6.9 | 39 | 8.2 | 19.4 |
| Pavg input | W | 550 | 1040 | 474 | 112 | 128.5 | 300 |
| Pavg output | W | 530 | 1000 | 388 | 65 | 56 | 280 |
| Transm. | % | 96 | 96 | 81 | 58 | 43 | 93 |
| frep | MHz | 0.5 | 1 | 0.5 | 1 | 1 | 0.5 |
Table 1. Summary of Multi-Pass Cell Systems for High Power and High Energy Lasers at High Repetition Rate
In this Letter, we demonstrate efficient nonlinear pulse compression of a 300 W, 500 kHz Yb-laser source using a two-stage, argon-filled MPC. The 404-fs input pulses are compressed to 19.4 fs, corresponding to a compression factor of approximately 20.8. A total output power of 280 W is achieved at the final output, with a long-term power stability of 0.12% root mean square (RMS) over four hours. This combination of high average power, high repetition rate, and excellent stability renders the source well suited for demanding end-applications such as time-resolved photoelectron spectroscopy.
2. Experimental Setup
The schematic of the experimental setup is presented in Fig. 1. The laser source employed in this study is a commercial femtosecond system operating at a central wavelength of 1030 nm. It delivers pulses with a duration of 404 fs at a repetition rate of 500 kHz, providing a typical average output power of 300 W. The initial output spectrum and temporal pulse profile of the laser are illustrated in Fig. 2.
![]()
Figure 1.Experimental setup.
![]()
Figure 2.Characterization of the input laser source. (a) Optical spectrum and (b) intensity autocorrelation trace of the pulses from the 300 W Yb laser. Inset figure: the output beam profile after the 300 W Yb laser.
The output from the commercial laser is first directed into an MPC1 for initial spectral broadening. The broadened pulses are then compressed in the first compression stage, which reduces the pulse duration from 404 to 86.1 fs. After appropriate mode matching, the pulses are coupled into a second MPC2 for further spectral broadening. They are subsequently introduced into the second compression stage, where the pulse width is compressed from 86.1 to 19.4 fs.
3. First Stage: MPC1
The first MPC stage is constructed with two-inch concave mirrors having a radius of curvature of 300 mm and a cavity length of 598 mm. Within this cell, the beam completes 23 round trips, resulting in a total nonlinear propagation length of 27.5 m. The fundamental eigenmode of the MPC, defined by its beam waist , is governed by the mirror radius of curvature () and the cavity length () and can be calculated using the ABCD matrix formalism[27,43–48]. Calculation yields a beam waist radius of 75 µm in MPC1. To assess and manage the nonlinear phase accumulation, the -integral per round trip is derived from nonlinear waveguide theory as follows:
![]()
Figure 3.Output characteristics after the first MPC stage (MPC1). (a) Broadened optical spectrum. (b) Intensity autocorrelation trace of the compressed pulses. Inset figure: the output beam profile after MPC1.
4. Second Stage: MPC2
The output from MPC1, with 294 W of average power, is first passed through a half-wave plate and thin-film polarizer pair to control the power injected into MPC2. The beam is then mode-matched to the fundamental eigenmode of MPC2 using a concave-convex mirror pair. Figure 4 maps the calculated beam waist across the (, ) parameter space. The solid black curve represents the parameter combinations that yield the target beam waist of . Our chosen configuration (, ), marked by the pink star, satisfies this condition. As derived from Eq. (1), the calculated -integral for a single round trip in the cavity is approximately 2.24 rad.
![]()
Figure 4.Distribution of beam waist ω0 on an L-R map, L = R (white dashed line), ω0 = 150 µm (black line), and best performance parameters chosen for the simulation: R = 600 mm, L = 1183 mm (pink star).
The energy fluence on the concave mirrors[44] was calculated using Eq. (2). For MPC2 (86 fs pulses after first-stage compression), the computed fluence is . The specified damage threshold for the mirrors is (20 ns, 20 Hz). Scaling this threshold to the specification (500 kHz, 86 fs) yields the derived threshold of . The operational fluence is a factor of below the respective scaled damage thresholds, ensuring a high margin of safety,
The cavity in MPC2 was equipped with two 3-inch concave mirrors having a radius of curvature of 600 mm, as well as a rectangular mirror located in front of the concave mirrors for injection and export of the laser. All mirrors featured a high-reflection coating () spanning 900–1200 nm. The number of round trips was set to 16 for this experiment, which was adjusted by fine-tuning the distance between the two concave mirrors. Over the operating bandwidth (980–1080 nm), the high-reflection mirrors contributed a total group delay dispersion (GDD) of less than . This dispersion was compensated using ten pairs of chirped mirrors along with thin fused-silica wedges for fine adjustment. The chirped mirrors provided a GDD of per bounce (nine pairs) and per bounce (one pair), all operating from 850 to 1200 nm.
Through optimization of the input laser power and argon gas pressure, we achieved a broadened spectrum spanning 950 to 1125 nm. The spectral broadening in MPC2 was further investigated as a function of argon pressure (0.5, 1.0, and 1.5 bar). The measured spectra exhibit minimal shift in the broadening extent across this pressure range (Fig. 5), consistent with a saturation of the dominant nonlinear process. Considering the maximum safe pressure (2 bar) for the cell windows, an argon pressure of 1.0 bar was selected for subsequent operation. The compressed pulse duration was measured to be 19.4 fs (Fig. 6), close to the Fourier-transform limit (FTL) of 17.8 fs retrieved from the measured spectrum. From the intensity autocorrelation trace, we calculate that approximately 76% of the total pulse energy is concentrated in the main peak, while the remaining 24% forms a low-intensity pedestal. This pedestal, visible in the autocorrelation trace (Fig. 6), is primarily attributed to uncompensated third-order dispersion (TOD) originating from the chirped mirrors and the fused-silica wedges. Although the GDD is well compensated over the 950–1125 nm bandwidth, the TOD introduced by the wedges and mirrors cannot be fully canceled with the current mirror set, leading to broadened wings of the compressed pulse. In future work, custom-designed chirped mirrors with tailored higher-order dispersion could further suppress the pedestal and potentially shorten the pulse to below 15 fs. The collimated and focused beam profiles of MPC2 after the chirped-mirror compressor are shown in the inset of Fig. 6. These profiles demonstrate excellent beam quality and the ability to achieve tight focusing, which is highly advantageous for subsequent applications such as high-harmonic generation experiments. The system delivers a final output power of 280 W, corresponding to a total transmission efficiency of 93% through the two cascaded MPC stages. The output power stability of MPC2 was characterized over four hours using an Ophir NOVA II power meter equipped with an FL1100 A-LP2-65 thermopile sensor (1 ms temporal resolution). The power stability measurement was performed in a standard optics laboratory with the temperature controlled at , a relative humidity of , and the optical table passively isolated from building vibrations. Under these conditions, the output power exhibited an RMS fluctuation of only 0.12% (Fig. 7) over four hours. This high stability is advantageous for applications such as high-harmonic generation and time-resolved measurements.
![]()
Figure 5.Evolution of the output spectrum with argon pressure in MPC2.
![]()
Figure 6.Characterization of the final compressed pulses from MPC2. Normalized intensity autocorrelation traces: measured pulse (blue curve) and Fourier-transform limit (FTL, gray area). Inset figure: the collimated beam profile (left) and the focused beam profile (right).
![]()
Figure 7.Power stability of the laser pulses from MPC2.
5. Conclusion
In summary, we have demonstrated a high-average-power, cascaded argon-filled MPC for nonlinear pulse compression at a 500 kHz repetition rate. The system compresses 300 W, 404 fs input pulses to 19.4 fs with an output power of 280 W, achieving a compression factor of greater than 20 and an overall transmission of 93%. The compressed output exhibits excellent stability, with a power fluctuation of 0.12% RMS over four hours. This work makes high-average-power, few-cycle pulses readily available for demanding applications like high-flux high-harmonic generation and time-resolved photoelectron spectroscopy.
Set citation alerts for the article