• Chinese Optics Letters
  • Vol. 24, Issue 10, 101404 (2026)
Yanjia Zhang1、2, Meizhi Sun1、2、*, Xinglong Xie1、2, Jun Kang1、2, Xiao Liang1、2, Ping Zhu1、2, Ailin Guo1、2, Qingwei Yang1、2, Haidong Zhu1、2, Huai Xiong1、2, Qunyu Bi3, Xuejie Zhang1、2, and Jianqiang Zhu1、2、**
Author Affiliations
  • 1National Laboratory on High Power Laser and Physics, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China
  • 2Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
  • 3Key Lab of Modern Optical Technologies of Jiangsu Province, Soochow University, Suzhou 215006, China
  • *Corresponding author: eric913@siom.ac.cn, jqzhu@siom.ac.cn
  • show less
    DOI: 10.3788/COL202624.101404 Cite this Article Set citation alerts
    Yanjia Zhang, Meizhi Sun, Xinglong Xie, Jun Kang, Xiao Liang, Ping Zhu, Ailin Guo, Qingwei Yang, Haidong Zhu, Huai Xiong, Qunyu Bi, Xuejie Zhang, Jianqiang Zhu, "Cascaded ultra-broadband optical parametric amplification with dual-duration pump pulses," Chin. Opt. Lett. 24, 101404 (2026) Copy Citation Text show less

    Abstract

    Optical parametric chirped pulse amplification (OPCPA) plays an important role for generation of ultrashort ultra-intense lasers. However, currently, achieving the output capability of multi-petawatt in a few-cycle duration is still a big challenge. Here, we propose a scheme with dual pump pulses of various durations for segmented parametric amplification of 800-nm-centered broadband chirped signal pulses based on a lithium triborate crystal. The matching conditions of this scheme were numerically analyzed. A signal spectrum ranging from 743 to 863 nm can be expected in the amplification with the front portion being 70 nm centered at 828 nm and the lateral portion being 50 nm centered at 763 nm and pumped by 1.5 ns pulse and 1.1 ns pulse, respectively. In a proof-of-principle experiment of a small optical aperture, we achieved an energy exceeding 50 mJ, a total gain of ∼2500, and a gain spectrum ranging from 742.8 to 863.4 nm with a bottom bandwidth exceeding 120 nm. The compressed pulse duration of 15.8 fs was measured and nearly coincident with the Fourier-transform-limited duration. This scheme will be adopted in the SG-II 5PW laser facility, and a delivery capability of up to ∼5 PW can be expected.
    © The Authors. Published by Chinese Laser Press under a Creative Commons Attribution 4.0 International License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.

    1. Introduction

    Electromagnetic field intensity in the finite spatial temporal domain is directly associated with the underlying physical regions[1]. Laser pulses are capable of providing a strong electromagnetic field, and the intensity (I) is determined by the pulse energy (E), duration (T), and optical spot size (S), I=E/(T·S). To meet the great requirements for various physical fields, in the last decades, high-power laser technologies have been developed rapidly, and a large number of ultrashort pulse laser sources have been installed in a large variety of laboratories all over the world[2]. Currently, the facilities with a peak power exceeding 10 PW, an intensity of up to 1023 W/cm2, as well as a high average power of hundreds of watts have been reported[3–6]. They provided strong tools and great opportunities for fundamental science and applications, such as high-field physics, attosecond physics, and ultrafast diagnosis[7–9].

    For more intense and higher power pulse generation, laser amplification technologies, which have delivery capacity in high energy, ultra-broad bandwidth and support shorter pulse durations, have been developed. There exist two technical routes with different types of gain media. Chirped pulse amplifications (CPAs) based on titanium-doped sapphires and rare earth ions-doped glasses from the petawatt to the ten petawatt have both been widely adopted with excellent performance in laser facilities, such as SULF, BELLA, and ELI-NP[10–12]. But there are several drawbacks in this route, e.g.,  the gain narrowing and redshift effects in high gain amplifiers, the transverse parasitic oscillation in large aperture gain media, the thermal loading effect, and beam quality degeneration issues. This restrained a delivery capacity of tens of nanometers in the spectrum, thereby supporting pulse duration around ten cycles. In 1992, combining CPA and optical parametric amplification (OPA), Dubietis et al. proposed the optical parametric chirped pulse amplification (OPCPA)[13]. OPCPA with nonlinear crystals has significant advantages, such as having an ultra-broad gain bandwidth, a tunable wavelength from the visible to the infrared region, a large gain in short crystal length, small thermal loading, and low concomitant noise generation[14]. OPA/OPCPA has been adopted in almost all of the frontends of the ultrashort high-power laser facilities because of its high gain, ultra-broad spectrum, and high contrast. For laser facilities with designed specifications of high energy (∼102 J) and ultrashort duration (∼5 cycles), a spectrum width greater than 100 nm is demanded in the large aperture main amplifiers, and this indicates that OPCPA is the only technical route. For instance, OPCPA is adopted in the facilities like SEL, OPAL, and XCELS, which are under construction and designed from tens of petawatts to sub-exawatt[15–17]. At present, the laser facilities that are fully based on OPCPA and that exceeded 1 PW delivery capacity include the CAEP-PW and SG-II 5PW[18,19]. The laser pulses were centered at 800 nm with a gain bandwidth of <100 nm, and the compressed pulse durations were around 7 cycles. The frontends of the OPAL and SEL centered at 900 nm now provide compressed pulses of 4–6 cycles, while the peak power is below 0.5 PW[15,16]. It is still a big challenge to realize multiple petawatts in few-cycle duration.

    For few-cycle multiple petawatts laser systems, there exist four issues: large aperture nonlinear crystals, intensity loading capacity, gain bandwidth, and high contrast under substantial conversion efficiency. Nonlinear crystals with available aperture exceeding 100 mm were restrained in lithium triborate (LBO)[15,18,19], yttrium calcium oxyborate (YCOB)[20], and potassium dideuterium phosphate (DKDP)[15–17,21]. Both the LBO and YCOB crystals have the potential delivery capacity around few hundreds of joules, while the DKDP crystals are able to support thousands of joules. It is a challenge to obtain crystals with high optical uniformity and large aperture. The intensity loading capacity is determined not only by the damage threshold of the crystal in bulk and the coating at the surface but also by the laser pulse wavelength and duration[22]. The gain bandwidth is close to the parametric bandwidth to some extent for parametric processes. The parametric bandwidths, when the pump is 526.5 nm and the signal is centered at 800 nm, are ∼70 nm in the LBO[18,19], ∼100 nm in the YCOB[20,21], and ∼50 nm in 95% ratio DKDP crystals[23].

    In the last several years, many new schemes have been proposed and experimentally demonstrated to achieve gain bandwidths of several hundred nanometers. In particular, a team from the Shanghai Institute of Optics and Fine Mechanics has adopted a dual-crystal segmented amplification scheme using LBO and YCOB crystals in combination to achieve a broad spectrum, although it is also still a struggle to use these crystals in high-energy, large-aperture amplifiers[24–28]. The main challenge lies in the availability and optical uniformity of large-aperture crystals, and using two different types of crystals introduces additional alignment complexity and interface losses, making this approach less attractive for high-energy systems. Innovative approaches have also been proposed, and photonic conversion efficiency close to the upper limitation was demonstrated while all of experimental delivery capacity was restrained below the joule level[29–33]. The noises in ultrashort laser systems manifest as pre-pulse and temporal pedestal before the signal pulse. They destroyed the target surface and influenced laser-plasma interactions of the main pulse[34]. Optical parametric fluorescence (OPF), inherent in OPA and exhibiting a pedestal over the time window of the pump pulse, is a significant issue. A large number of approaches, such as the OPCPA in the picosecond domain and in-band noise filtering, have been used to restrain OPF[35,36] in preamplifiers and cannot be directly adopted in large aperture, high energy amplifiers. Considering the gain property of the OPF and signal in our previous work, the scheme proposed in this paper with the phase-mismatched factor being much smaller than the traditional way has the potential of contrast enhancement along the parametric process[37].

    In 2018, the SG-II 5PW laser facility realized a delivery capacity of 1.76 PW[19]. The signal wavelength was chosen at 800 nm because the high quality seed pulses were provided by a mode-locked Ti:sapphire oscillator, and the photonic conversion efficiency at 800 nm was higher than that at 900 nm. This facility operated well since its installation and the contrast as well as the focusing features were significantly improved[38,39]. Experimental investigations on ignition-confined fusion diagnosis, proton acceleration, and laser wake-field acceleration were accomplished with this platform[9,40–43]. In this paper, we propose a new scheme with dual pump pulses of various durations for segmented parametric amplification based on an LBO crystal and provide a proof-of-principle experiment demonstration. Compared with the single pump pulse scheme, which can only effectively support a spectral width of a small amount, if the pump pulse width is too long, the increase in OPF amplification will lead to severe degradation of the signal-to-noise ratio, and this scheme could support a larger bottom bandwidth. Considering that the SG-II facility can provide two pump beams with different durations as well as energy exceeding 200 J after second-harmonic generation (SHG), this scheme will be adopted in the second stage of OPCPA, and a delivery capacity of 5 PW peak power (80 J in 16 fs) can be expected after compression.

    2. Theoretical Analysis

    2.1. Conceptual designs

    In this scheme, as shown in Fig. 1, two stages of OPA are designed for amplifying the chirped signal with two separated pump beams. The chirped ratio of the signal is Cs. In the first stage amplifier (Amplifier-1) with the nonlinear crystal LBO1 in the XOY principle plane, the short wavelength portion centered at wavelength λ01 of the signal is spatially and temporally overlapped with the pump pulse (Pump-1) at a noncollinear angle α1 and a phase-matched angle at (θ1,φ1), supporting a parametric bandwidth Δλ1. In the second stage amplifier (Amplifier-2) with the nonlinear crystal LBO2, the long wavelength portion centered at wavelength λ02 is spatially and temporally overlapped with the pump pulse (Pump-2) at a noncollinear angle α2 and a phase-matched angle at (θ2,φ2), supporting a parametric bandwidth Δλ2. The synchronization between the signal and pump beams can be precisely controlled at an order of several picoseconds (rms) in laser facilities. Different pulse durations (Tp1 and Tp2) of the two pump beams are adopted and determined by the chirp rate of the signal and parametric bandwidth, Tp1≈Cs*Δλ1 and Tp2≈Cs*Δλ2. The beam apertures Φ of the two pump lights are the same, with energies Ep1 and Ep2 and intensities Ip1≈Ep1/(Tp1·Φ) and Ip2≈Ep2/(Tp2·Φ), respectively.

    Conceptual design of the cascaded ultra-broadband optical parametric amplification with dual-duration pump, depicting the temporal evolution of the pulse at different amplification stages.

    Figure 1.Conceptual design of the cascaded ultra-broadband optical parametric amplification with dual-duration pump, depicting the temporal evolution of the pulse at different amplification stages.

    The SG-II 5PW and CAEP-PW facilities are the two currently reported femtosecond laser systems that are centered at 800 nm wavelength and fully based on OPCPA with a delivery capacity exceeding 1 PW[18,19]. The main amplifiers of these two facilities are based on LBO crystals with an aperture of 100 mm scale while supporting a gain bandwidth well below 100 nm. At the injection end of the main amplifier in SG-II 5PW, the chirp rate is 21.3 ps/nm, and the signal pulse width is ∼2.6 ns. Due to the loss in the chromatic aberration compensation module, the signal energy is reduced to ∼38 mJ with an intensity ∼0.2 MW/cm2. Here, we provide numerical analysis and proof-in-principle experimental demonstration on the cascaded ultra-broadband optical parametric amplification with dual-duration pump pulses for the potential utilization in the main amplifier of the SG-II 5PW laser systems.

    2.2. Phase-matching conditions

    With the determined pump wavelength λp, phase-mismatching ΔΦ requires |Δk(α,φpm,λs,λs0)·Lc|≤π, where α is the noncollinear angle, φpm is the phase-matching angle, Lc is the crystal length, λs0 is the central wavelength of the signal, and λs is the wavelengths of the signal that satisfy phase matching. We define λsmin and λsmax as the minimum and maximum of λs. Considering the temporal coupling between the pump and the signal pulses, it is required that the central wavelength of the signal corresponds to the center of the pump pulse. Thus, the effective parametric bandwidth is defined as Δλpara=min(|λsmax−λs0|,|λs0−λsmin|). Numerical calculations were performed on the phase matching characteristics in the XOY principle plane of a 20-mm-long LBO crystal. The pump at 526.5 nm from the SHG of the Nd:glass laser and signal around 800 nm are phase-matched with type-I for the utilization in master amplifier of SG-II 5PW system. The parametric bandwidth, noncollinear angle, phase-matching angle, acceptance angle, as well as the λsmin and λsmax are shown in Fig. 2, corresponding to different central wavelengths λs0.

    Phase-matching conditions in XOY principle plane of the LBO crystal for various signal central wavelengths. (a) Parametric bandwidth (blue) and noncollinear angle (green), (b) phase-matching angle (blue) and acceptance angle (green), (c) phase-matching signal wavelengths of the upper limitation (red), the lower limitation (blue), and the central wavelength (black).

    Figure 2.Phase-matching conditions in XOY principle plane of the LBO crystal for various signal central wavelengths. (a) Parametric bandwidth (blue) and noncollinear angle (green), (b) phase-matching angle (blue) and acceptance angle (green), (c) phase-matching signal wavelengths of the upper limitation (red), the lower limitation (blue), and the central wavelength (black).

    The parametric bandwidth Δλpara is shown by the blue line in Fig. 2(a). It indicated how difficult it is to obtain a large parametric bandwidth in the short wavelength region. For the central wavelength ∼803 nm with an optimal noncollinear angle of 1.278°, the maximum parametric bandwidth was only 75 nm, which was demonstrated by the experiment in the main amplifier of the CAEP-PW facility[18]. As a result, the optical parametric amplifier based on the LBO crystal with a pump pulse duration of ∼2.6 ns cannot support an amplification spectrum bandwidth of 120 nm centered around 800 nm, which was required in the SG-II 5PW system. In our scheme, the parametric bandwidth exceeds 50 nm for a center wavelength of 768 nm, corresponding to a noncollinear angle of 1.01°, and a phase matching angle of (θ=90°, φ=12.49°) is shown in Fig. 2(b). This indicated a gain spectrum region of 743–793 nm [Fig. 2(c)] with a pump pulse of 1.1 ns duration. Similarly, for the signal spectrum portion of [793 nm, 863 nm] centered at 828 nm, the optimal noncollinear angle is 1.327°, and the phase matching angle (θ=90°, φ=14.16°), with which a parametric bandwidth of 106 nm and a phase matching spectral range of [λsmin,λsmax]≈[775 nm,881 nm] could be expected, far beyond the required 70 nm with a pump duration of ∼1.5 ns. The acceptance angles were ∼2.5 mrad, which is much larger than those in other crystals, such as BBO, YCOB, and DKDP[20,23].

    Figure 3(a) presents the phase matching angles for noncollinear angles of 1.013°, 1.278°, and 1.327°, corresponding to perfect phase-matching at 768 nm, 803 nm, and 828 nm, respectively. The phase mismatch factor under these parameters is shown in Fig. 3(b). For the second segment of the signal within the range of 793–863 nm, the phase mismatch factor ΔΦ is less than 0.64π. A smaller phase mismatch factor ensured a more dominant competitive ability of the signal compared to the OPF, which was beneficial for noise suppression during the nonlinear process[37].

    (a) Phase matching angles and (b) phase mismatching factors when adopting various noncollinear angles for central wavelengths at 768 nm (black), 803 nm (red), and 828 nm (green).

    Figure 3.(a) Phase matching angles and (b) phase mismatching factors when adopting various noncollinear angles for central wavelengths at 768 nm (black), 803 nm (red), and 828 nm (green).

    2.3. Damage threshold and loading capacity

    Our scheme also has advantages in loading capacity. The damage threshold of the materials under monochromatic laser pulse with different durations can be estimated by an empirical formula, Tx ns·x−α=T1 ns[22]. Considering the average intensity I≈T/x for pulses with top-hat spatial-temporal profiles, we can get I1.5 ns=1.32I2.6 ns and I1.1 ns=1.54I2.6 ns. This indicates the requirement of a shorter crystal length for the same conversion efficiency in OPA. In our cascaded dual-duration pump scheme, each high-intensity pump pulse temporally overlaps only with the low-intensity injected signal, mitigating multi-wavelength loading and enhancing overall capacity.

    The SG-II facility can independently control two beams with pulse durations of 1.1 ns and 1.5 ns, synchronized to 7.6 ps (rms)[44]. To obtain a uniformly amplified output signal spectrum, the intensities for both of the two pump beams were set to ∼2.2 GW/cm2 so that the maximum energy flux density was ∼4.3 J/cm2, well below the damage threshold. By numerical simulation of three coupled-wave equations[45], crystal lengths of 18 mm for both of the two OPA stages were able to meet the requirements on high conversion efficiency, shown in Fig. 4(a). Amplifier-1 taking 5% higher conversion efficiency than Amplifier-2 was due to the higher single-photon energy at 768 nm. A total spectrum ranging from 743 to 863 nm could be expected, as shown in Fig. 4(b). The optimized specifications are presented in Table 1. With a total pump energy of 280 J and a conversion efficiency of 40%, a signal pulse energy exceeding 112 J can be expected. This means that a compressed pulse energy higher than 84 J can be achieved after the master compressor with a transmission efficiency of ∼75%. We took advantage of the frontend of the SG-II 5PW laser facility to give a proof-of-principle experimental demonstration. The two LBO crystals adopted were 18 mm in length, and the incident intensities of the pump and chirped signal pulses were close to those in Table 1.

    StageEp (J)φp (mm × mm)Tp (ns)Ip (GW/cm2)Lc (mm)λs0 (nm)α (degree)θ, φ (degree)ΔλG (nm)|ΔkLc| (rad)
    Amplifier-112070 × 701.12.2187681.0190, 12.4950<π
    Amplifier-216070 × 701.52.2188281.3390, 14.1670<0.6π

    Table 1. Optimized Design of Cascaded OPA with Dual-Duration Pump in SG-II 5PW Facility

    (a) Conversion efficiency and (b) amplification spectrum for the two stages of cascaded optical parametric amplification with a pump pulse duration of 1.1 ns (blue) and 1.5 ns (red).

    Figure 4.(a) Conversion efficiency and (b) amplification spectrum for the two stages of cascaded optical parametric amplification with a pump pulse duration of 1.1 ns (blue) and 1.5 ns (red).

    3. Experimental Demonstration

    3.1. Experiment setup

    In the experiment, the frontend of the SG-II 5PW laser, including the oscillator, stretcher, pre-compressor, pump laser, and part of the amplifier, was shared for the incidence, as shown in Fig. 5. For the pump, a single longitudinal-mode laser at 1064 nm provided continuous light, which was trimmed to a pulse train with a repetition rate of 1 Hz by an acousto-optic (AO) chopper. It was successively shaped and amplified to 700 mJ by arbitrary waveform generator (AWG), fiber amplifier, diode-pumped Nd:YAG regenerative amplifier, and three stages of Nd:YAG rod amplifier. A pump pulse of energy 490 mJ at 532 nm was achieved after SHG in a potassium titanyl phosphate (KTP) crystal. It possessed the characteristics of spatial-temporal top-hat profiles with a duration of 2.2 ns and an aperture of φ10 mm. The pump was split by two stages of attenuators, which consisted of a half-wave plate (HWP) and a polarizing beam splitter (PBS) coated at the Brewster angle. A pulse of 90 mJ, utilized as the pump of the preamplifier, was split by the first stage of the attenuator. The remaining beam of 400 mJ was controlled by the second stage of the attenuator, and 320 mJ was divided into two parts and time-delayed properly for the cascaded ultra-broadband optical parametric amplifiers.

    Scheme of the experimental configuration. HWP, half-wave plate; PBS, polarizing beam splitter; AP, attenuator plate; CM, chirped mirror; BS, beam splitter.

    Figure 5.Scheme of the experimental configuration. HWP, half-wave plate; PBS, polarizing beam splitter; AP, attenuator plate; CM, chirped mirror; BS, beam splitter.

    A Ti:sapphire mode-locked oscillator provided the signal of 2 nJ, 10 fs pulses at a repetition rate of 78 MHz. The femtosecond pulses were temporally expanded to a 2.5 ns full-width at half-maximum (FWHM) in an Öffner stretcher with a 25.5 ps/nm chirped ratio and then injected into the pre-compressor for precise dispersion management with a −4.2 ps/nm chirped ratio. The chirped pulses before injected into the preamplifier were of a spectral FWHM bandwidth of ∼100 nm and a full bandwidth ranging from 742 to 866 nm, which means the temporal bottom width is ∼2.6 ns with a 21.3 ps/nm chirped ratio. The energy per pulse was reduced to 60 pJ. The synchronization accuracy between the pump and signal pulses was measured at 10 ps (rms).

    The preamplifier consisted of four BBO crystals. In the prior two BBO crystals, the pump and signal were injected with an inner noncollinear angle of 2.37° and a cutting angle of 23.82°, corresponding to a phase-matching spectrum centered at 808 nm. In the latter two BBO crystals, the inner noncollinear angle of 2.22° and cutting angle of 23.54° were aligned for phase matching of the spectrum region centered at 755 nm. Pulses with an energy of 8 mJ were delivered and the total gain was up to 1.3×108. The waveforms of the pump and amplified signal were measured by using a photodiode (Thorlab, 5 GHz) and an oscilloscope (WaveRunner, 9104). As shown in Fig. 6(a), the signal FWHM bandwidth was ∼2.55 ns. A gain bandwidth ranging from 742 to 866 nm was achieved and is shown by the red line in Fig. 6(b) (Ocean Optics HR4000+). The OPF spectrum indicated a higher gain at a short wavelength region for the compensation of lower intensity at the trailing edge of the incident signal pulses. The normalized near-field distribution of the signal pulses after the preamplifier is illustrated in Fig. 6(c).

    After preamplifier, (a) the normalized waveforms of the pump (blue) and amplified signal (red), (b) the spectra of the signal (red) and OPF (black), and (c) the near field of the signal pulse.

    Figure 6.After preamplifier, (a) the normalized waveforms of the pump (blue) and amplified signal (red), (b) the spectra of the signal (red) and OPF (black), and (c) the near field of the signal pulse.

    Pump pulses of 320 mJ were divided equally into two bunches by a 50/50 beam splitter. Both of the two bunches were beam shrunk to φ2 mm with a Galilean configuration so that the pump intensity at the crystal surface was ∼2.2 GW/cm2, which was required in Table 1. Phase-matching parameters with pump pulses at 532 nm were slightly different from those with pump pulses at 526.5 nm, while the output results remain essentially the same. In Amplifier-1, the noncollinear angle was set at 0.758°, and the phase-matching angle was set at 10.86°, supporting a parametric bandwidth of ∼46 nm at 768 nm. In Amplifier-2, the noncollinear angle was set at 1.213°, and the phase-matching angle was set at 13.13°, supporting a parametric bandwidth of ∼90 nm at 828 nm. This indicated that a gain spectrum ranging from 743 to 863 nm was capable of being realized with both pump pulses at 532 nm and 526.5 nm in this scheme.

    3.2. Experiment results

    Similar to the amplified spontaneous emission (ASE), which indicates the gain characteristics of an amplifier based on the media with population inversion, the gain characteristics of an OPA amplifier can be presented by an OPF spectrum, which is achieved when the pump is injected into the amplifier while the signal is blocked[46]. In this experiment, the signal as well as the OPF from the preamplifier was injected into the lateral two stages of the LBO crystals. It should be noted that the OPF was measured after the LBO crystals were seeded by the OPF output from the preamplifier. After Amplifier-1, the spectra of signal and the OPF are depicted by the red and black lines in Fig. 7(a). The signal spectrum with an intensity higher than ten percent of the maximum (>10%·Imax) from 741 to 789 nm, and the amplitude of the OPF reached the highest, around 763 nm. To get the amplification performance of Amplifier-2, the signal transmitted through LBO-1 with the pump beam was blocked and injected into LBO-2. The signal spectrum after Amplifier-2 is provided by the red line in Fig. 7(b). The signal spectrum region (>10%·Imax) ranged from 775 to 864 nm and the amplitude of the OPF reached the highest around 828 nm, as shown by the black line in Fig. 7(b). When both of the two amplifiers worked on, the signal spectrum is depicted by the red line in Fig. 7(c). The whole signal spectrum region (>10%·Imax) ranged from 742.8 to 863.4 nm, with a bottom bandwidth exceeding 120 nm. The OPF spectrum, after the whole amplification chain covered the similar region with the amplified signal, indicated a higher gain at the short wavelength side than the long wavelength side, which was required to compensate for the initial weak seed signal at the short wavelength before incidence. The measured spectrum was essentially consistent with that in Fig. 4(b).

    Normalized spectra of the signal (red) and OPF (black) pulses when Amplifier-1 (a) and Amplifier-2 (b) operated alone and when both amplifiers were turned on (c).

    Figure 7.Normalized spectra of the signal (red) and OPF (black) pulses when Amplifier-1 (a) and Amplifier-2 (b) operated alone and when both amplifiers were turned on (c).

    With the incident chirped signal from the preamplifier, the temporal profiles of the signal after Amplifer-1, Amplifier-2, and the whole system were measured and are depicted in Fig. 8(a). The FWHM durations were approximately 1.1 ns, 1.7 ns, and 2.6 ns, respectively. The energy of signal pulses delivered from the whole amplification chain was measured and is shown in Fig. 8(b), corresponding to various incident signal energies. As illustrated by the embedded graph, it exhibited a high gain exceeding 1000 and an energy around 60 mJ if the incident signal energy was well below 60 µJ. As the conversion efficiency is not sensitive to the injected seed energy, increasing the injected signal energy can help reduce the crystal length while maintaining a high conversion efficiency. When the energy of the incident signal was ∼20 μJ, the intensity was equal to that incident into the master amplifier in the SG-II 5PW facility, and the output signal energy exceeded 50 mJ with a gain ∼2500, which was close to the requirement of the master amplifier. The total energy conversion efficiency was merely 18.75% because the pump and signal pulses were only partially overlapped in temporal domain. We also measured the delivery capacity for different pump energies when the incident signal energy was fixed at 20 µJ and 30 µJ, as shown in Fig. 8(c). The output signal energy for incidence 30 µJ was higher than that for incidence 20 µJ, which indicated the amplifier operating in the unsaturated region.

    (a) Normalized waveforms of the signal pulses when Amplifier-1 (blue) and Amplifier-2 (red) operated alone and when both amplifiers were turned on (black). (b) Energy of the signal pulses delivered from the whole amplification chain. (c) Delivery capacity for different pump energies when the incident signal energy was fixed at 20 µJ and 30 µJ.

    Figure 8.(a) Normalized waveforms of the signal pulses when Amplifier-1 (blue) and Amplifier-2 (red) operated alone and when both amplifiers were turned on (black). (b) Energy of the signal pulses delivered from the whole amplification chain. (c) Delivery capacity for different pump energies when the incident signal energy was fixed at 20 µJ and 30 µJ.

    Signal pulses were delivered into a pair of chirped mirrors, and the beam was expanded before being injected into a grating-pair compressor for precise dispersion management. The compressed pulse traces were measured by a homemade autocorrelator, shown by the black line in Fig. 9(a). The FWHM pulse width was 15.8 fs with a Gaussian profile fitting. The Fourier-transform-limited (FTL) pulse was also provided by the red line in Fig. 9(a), and the duration exhibited ∼15.5 fs (5.7 cycles at 800 nm central wavelength). The spatial profile of the amplified signal was presented in Fig. 9(b). The beam quality was not deteriorated.

    (a) Compressed pulse traces (black) and calculated Fourier-transform-limited (FTL) pulse (red). (b) Near-field distribution.

    Figure 9.(a) Compressed pulse traces (black) and calculated Fourier-transform-limited (FTL) pulse (red). (b) Near-field distribution.

    4. Conclusion

    In summary, in this paper we propose a new scheme with dual pump pulses of various durations for segmented parametric amplification. Numerical analyses are provided for its potential utilization in a master amplifier based on LBO crystals of SG-II 5PW to realize multiple petawatts delivery capacity in few-cycle duration. We carried out a proof-of-principle experiment based on the frontend of the SG-II 5PW laser facility, under the condition that the incident intensities of the pump and chirped signal pulses and the LBO crystal lengths were close to those in the numerical simulations. We achieved a gain spectrum ranging from 742.8 to 863.4 nm with a bottom bandwidth exceeding 120 nm, with a total net gain of ∼2500 in experiment. The pulse duration after compression was measured at 15.8 fs (∼5.8 cycles at 800 nm). This verifies its application prospects for a delivery capability of up to ∼5 PW (80 J/16 fs) in the SG-II 5PW laser facility.

    References

    [1] G. Mourou, T. Tajima. More intense, shorter pulses. Science, 331, 41(2011).

    [2] C. N. Danson, C. Haefner, J. Bromage et al. Petawatt and exawatt class lasers worldwide. High Power Laser Sci. Eng., 7, e54(2019).

    [3] A. Dubietis, A. Matijošius. Table-top optical parametric chirped pulse amplifiers: past and present. Opto-Electron. Adv., 6, 220046(2023).

    [4] F. Lureau, G. Matras, O. Chalus et al. High-energy hybrid femtosecond laser system demonstrating 2×10 PW capability. High Power Laser Sci. Eng., 8, e43(2020).

    [5] J. W. Yoon, Y. G. Kim, I. Choi et al. Realization of laser intensity over 1023 W/cm2. Optica, 8, 630(2021).

    [6] M. K. R. Windeler, K. Mecseki, A. Miahnahri et al. 100 W high-repetition-rate near-infrared optical parametric chirped pulse amplifier. Opt. Lett., 44, 4287(2019).

    [7] A. Hurricane, P. K. Patel, R. Betti et al. Physics principles of inertial confinement fusion and US program overview. Rev. Mod. Phys., 95, 025005(2023).

    [8] H. Y. Kim, M. Garg, S. Mandal et al. Attosecond field emission. Nature, 613, 662(2023).

    [9] L. J. Li, Z. T. Lu, X. L. Xie et al. Ultrafast characterization of plasma critical surface evolution in inertial confinement fusion experiments with chirped laser pulses. High Power Laser Sci. Eng., 13, e13(2025).

    [10] W. Li, Z. Gan, L. Yu et al. 339 J high-energy Ti:sapphire chirped-pulse amplifier for 10 PW laser facility. Opt. Lett., 43, 5681(2018).

    [11] K. Nakamura, H.-S. Mao, A. J. Gonsalves et al. Diagnostics, control and performance parameters for the BELLA high repetition rate petawatt class laser. IEEE J. Quantum Electron., 53, 1200121(2017).

    [12] C. Radier, O. Chalus, M. Charbonneau et al. 10 PW peak power femtosecond laser pulses at ELI-NP. High Power Laser Sci. Eng., 10, e21(2022).

    [13] A. Dubietis, G. Jonusauskas, A. Piskarskas. Powerful femtosecond pulse generation by chirped and stretched pulse parametric amplification in BBO crystal. Opt. Commun., 88, 437(1992).

    [14] Z. Y. Li, Y. X. Leng, R. X. Li. Further development of the short-pulse petawatt laser: trends, technologies, and bottlenecks. Laser Photonics Rev., 17, 2100705(2023).

    [15] X. Wang, X. Lu, J. Chen et al. 13.4 fs, 0.1 Hz OPCPA front end for the 100 PW-class laser facility. Ultrafast Sci., 2022, 9894358(2022).

    [16] J. Bromage, S. W. Bahk, I. A. Begishev et al. Technology development for ultraintense all-OPCPA systems. High Power Laser Sci. Eng., 7, e4(2019).

    [17] E. Khazanov, A. Shaykin, I. Kostyukov et al. eXawatt Center for Extreme Light Studies. High Power Laser Sci. Eng., 11, e78(2023).

    [18] X. M. Zeng, K. N. Zhou, Y. L. Zuo et al. Multi-petawatt laser facility fully based on optical parametric chirped-pulse amplification. Opt. Lett., 42, 2014(2017).

    [19] J. Q. Zhu, X. L. Xie, M. Z. Sun et al. Analysis and construction status of SG-II 5PW laser facility. High Power Laser Sci. Eng., 6, e29(2018).

    [20] M. Z. Sun, J. Kang, X. Liang et al. Demonstration of a petawatt-scale optical parametric chirped pulse amplifier based on yttrium calcium oxyborate. High Power Laser Sci. Eng., 11, e2(2023).

    [21] S. Buck, P. Oliveira, T. Angelides et al. A review of optical parametric amplification at the Vulcan laser facility. Photonics, 11, 495(2024).

    [22] F. Rainer, C. L. Vercimak, D. Milam et al. Measurements of the dependence of damage thresholds on laser wavelength, pulse duration and film thickness. Laser Induced Damage in Optical Materials: 1983, 58(1985).

    [23] X. Liang, X. L. Xie, C. Zhang et al. Broadband main OPCPA amplifier at 808 nm wavelength in high deuterated DKDP crystals. Opt. Lett., 43, 5713(2018).

    [24] B. E. Schmidt, N. Thiré, M. Boivin et al. Frequency domain optical parametric amplification. Nat. Commun., 5, 3643(2014).

    [25] D. E. Rivas, A. Borot, D. E. Cardenas et al. Next generation driver for attosecond and laser-plasma physics. Sci. Rep., 7, 5224(2017).

    [26] Z. Li, Y. Kato, J. Kawanaka. Simulating an ultra-broadband concept for exawatt-class lasers. Sci. Rep., 11, 151(2021).

    [27] L. J. Qiu, M. Z. Sun, X. L. Xie et al. Experimental demonstration on 400 nm-scale bandwidth optical parametric chirped-pulse amplification based on mixed cascaded crystals. Opt. Express, 32, 7633(2024).

    [28] L. Xu, E. J. Takahashi. Dual-chirped optical parametric amplification of high-energy single-cycle laser pulses. Nat. Photonics, 18, 99(2024).

    [29] J. G. Ma, K. N. Xiong, P. Yuan et al. Demonstration of 85% pump depletion and 10−6 noise content in quasi-parametric chirped-pulse amplification. Light Sci. Appl., 11, 269(2022).

    [30] M. Sun, X. Xie, J. Zhu et al. Optical parametric amplification in crossed Fabry-Perot cavities. Laser Photonics Rev., 18, 2300979(2024).

    [31] J. H. Nägele, T. Steinle, J. Thannheimer et al. Dispersion-engineered multipass optical parametric amplification. Nature, 647, 74(2025).

    [32] G. Jansonas, R. Budriūnas, G. Valiulis et al. Polarization-based idler elimination: enhancing the efficiency of optical parametric amplification. Opt. Express, 31, 19794(2023).

    [33] Z. Wang, L. Xu, S. Peng et al. High efficiency broadband parametric amplification assisted by second harmonic generation. Opt. Laser Technol., 181, 111887(2025).

    [34] M. Schollmeier, A. B. Sefkow, M. Geissel et al. Laser-to-hot-electron conversion limitations in relativistic laser matter interactions due to multi-picosecond dynamics. Phys. Plasmas, 22, 043116(2015).

    [35] A. Kessel, V. E. Leshchenko, O. Jahn et al. Relativistic few-cycle pulses with high contrast from picosecond-pumped OPCPA. Optica, 5, 434(2018).

    [36] J. Wang, J. G. Ma, P. Yuan et al. In-band noise filtering via spatio-spectral coupling. Laser Photonics Rev., 12, 1700316(2018).

    [37] M. Z. Sun, X. L. Xie, J. Q. Zhu et al. Experimental demonstration of 1011 temporal contrast in pure nanosecond optical parametric chirped pulse amplifiers. Appl. Opt., 60, 2056(2021).

    [38] Z. R. Cui, J. Kang, A. L. Gu et al. Dynamic chromatic aberration pre-compensation scheme for ultrashort petawatt laser systems. Opt. Express, 27, 16812(2019).

    [39] D. Zhang, P. Zhu, Y. Yi et al. Comprehensive investigation on the plasma mirror temporal contrast enhancement instrument at SG-II 5PW laser facility. Rev. Sci. Instrum., 97, 013003(2026).

    [40] Z. Cui, J. Kang, X. Xie et al. Compensation for chromatic aberration in femtosecond petawatt laser systems based on zoom image transfer. Chin. J. Lasers, 46, 905001(2019).

    [41] X. Liang, Y. Yi, S. Li et al. A laser wakefield acceleration facility using SG-II petawatt laser system. Rev. Sci. Instrum., 93, 033504(2022).

    [42] Z. Lu, X. Xie, X. Liang et al. Effect of laser wavelength on growth of ablative Rayleigh–Taylor instability in inertial confinement fusion. Matter Radiat. Extremes, 10, 027403(2025).

    [43] R. U. Haq, M. Rezaei-Pandari, X. Xie et al. Multi-GeV electron beam generation via two-stage laser wakefield acceleration. Sci. Rep., 15, 42290(2025).

    [44] J. Zhu, J. Zhu, X. Li et al. Status and development of high-power laser facilities at the NLHPLP. High Power Laser Sci. Eng., 6, e55(2018).

    [45] A. Andrianov, A. Szabo, A. Sergeev et al. Computationally efficient method for Fourier transform of highly chirped pulses for laser and parametric amplifier modeling. Opt. Express, 24, 25974(2016).

    [46] J. Ma, J. Wang, P. Yuan et al. Quasi-parametric amplification of chirped pulses based on a Sm3+-doped yttrium calcium oxyborate crystal. Optica, 2, 1006(2015).

    Yanjia Zhang, Meizhi Sun, Xinglong Xie, Jun Kang, Xiao Liang, Ping Zhu, Ailin Guo, Qingwei Yang, Haidong Zhu, Huai Xiong, Qunyu Bi, Xuejie Zhang, Jianqiang Zhu, "Cascaded ultra-broadband optical parametric amplification with dual-duration pump pulses," Chin. Opt. Lett. 24, 101404 (2026)
    Download Citation